CONDUCTOR

EC Grade Annealed Copper With High Flexibility Class 5 and Uniform Resistance Properties.

INSULATION

All Insulation Grades In PVC exceeds the requirements As Stated In Is 5831. All Grades Of Insulation Are "RoHS" Compliant With 70°c And 85°c Rating

MARKING

The cables are printed with generic marking AXELON

INSULATION COLOURS

Red, Yellow, Blue, Green, Black, Yellow / Green, Grey, White. Other colors available on request.

SHEATH COLOURS

Black, Ivory, Blue, White other colors available on request.

PACKING

Standard packing of 100 mtr. in coils. Longer length available on request

 

MULTICORE FLEXIBLES

Type of Insulation Type of Sheathing Applicable Standards Typical Applications
Standard PVC Standard PVC, HRPVC IS 694, BS 6500, IEC 60227,
DIN VDE-0281
Power Cords for appliance, temporary
power supplies.
3 core flat cables are suitable for
submersible pump applications.
Heat Resistant PVC up to 105°c Standard PVC, HRPVC IS 694, BS 6500, IEC 60227,
DIN VDE-0281
Hi-power appliances, ovens,
temporary power supply in
higher temperature areas.
Standard PVC of FRLS FRLS (Flame Retardant Low Smoke) IS 694, BS 6500, IEC 60227,
DIN VDE-0281, IEC 60754-1, IEC 60332-1,
BS-4066-1, ASTMD 2843, ASTMD - 2863
Power cords for application used
in fire prone areas, flame proof
equipments, machine tools used in critical
locations and heat zones.

SIZE, DIMENSIONS & RATINGS

Size
Sq. mm
No/Nomial
Dia Of
Conductor
Strands*
mm
Nominal
Insulation
Thickness(mm)
mm 
Nominal Thickness of Sheath Approx. Overall  diameter Voltage /Amp
per mtr.
Max. D.C.
Conductor
Resistance
at 20°c
ohms
2
core
mm 
3
core
mm 
4
core
mm 
5
core
mm 
2
core
mm 
3
core
mm 
4
core
mm 
5
core
mm 
Current Rating
amps
DC or
single
phase
AC
mv
3
Phase
AC
mv 
0.50 16/0.20 0.6 0.9 0.9 0.9 0.9 6.9 7.3 8.0 8.7 4.0 83.0 72.0 39.0
0.75 24/0.20 0.6 0.9 0.9 0.9 0.9 7.3 7.7 8.4 9.2 7.0 56.0 48.0 26.0
1.00 32/0.20 0.6 0.9 0.9 0.9 1.0 7.6 8.1 8.8 9.6 11.0 43.0 37.0 19.5
1.50 30/0.25 0.6 0.9 0.9 1.0 1.0 8.9 9.4 10.4 11.4 14.0 31.0 26.0 13.3
2.50 50/0.25 0.7 1.0 1.0 1.0 1.0 10.3 10.9 12.0 13.2 19.0 18.0 16.0 7.98
4.00 56/0.30 0.8 1.0 1.0 1.0 1.1 11.6 12.4 13.6 15.3 26.0 11.0 9.6 4.95
6.00 84/0.30 0.8 1.1 1.2 1.2   13.0 13.8 15.5 0.0 33.0 7.3 6.0 3.3
10.00 141/0.30 1.0 1.3 1.4 1.4   16.5 17.7 19.5 0.0 45.0 4.4 3.5 1.91
16.00 226/0.30 1.0 1.4 1.4 1.4   19.4 20.6 23.0 0.0 60.0 2.8 2.2 1.21
25.00 196/0.40 1.2 1.4 1.5 1.6   23.8 25.6 28.5 0.0 75.0 0.2 1.4 0.78
35.00 276/0.40 1.2 1.6 1.6 1.7   27.2 29.3 32.7 0.0 95.0 0.2 1.0 0.554
50.00 396/0.40 1.4 2.0 2.0 2.0   32.0 34.6 38.6 0.0 125.0 0.2 0.8 0.386
70.00 360/0.50 1.4 2.2 2.2 2.2   36.8 39.6 44.3 0.0 170.0 0.2 0.6 0.272

Note: * The number and diameter of conductor strands are for reference only. Conductor resistance as per IS:8130 is the governing criteria
The above data is indicative and may be revised without prior intimation. As per IS:3961 (Part V)-1968